This equipment is a new type model, characterized by a compact design and aesthetic appearance. The outer panels of the machine parts are made of aluminum alloy and high quality 304 stainless steel; All parts in contact with the product are made of 316 stainless steel, which complies with GMP requirements and ensures low weight of the equipment and ease of transportation.
| Name | Technical Parameters |
| Production speed (for 16 channels) | Maximum production speed 12,000 pcs/min (depending on bottle size, product characteristics and filling volume) |
| Quantity per bottle | 1–9999, freely set |
| Counted product size (mm) | Tablets with a diameter of 3–23 mm, capsules No. 0–5, pills with a diameter of 3–12 mm |
| Bottle volume (ml) | 15–300 |
| Voltage/Frequency (V/Hz) | Single phase AC 220V, 50/60Hz |
| Compressed air source | 0.6 MPa |
| Overall dimensions of the main unit (L×W×H) (mm) (for 16 channels) | 2200×1800×1850 (height adjustable) |
| Power (kW) | 1.5 |
| Air flow (l/min) | 4 |
| Weight (kg) (approx.) | 750 |
1. This equipment is a new type model, featuring compact structure and aesthetic appearance. The outer panels of the machine parts are made of aluminum alloy and high quality 304 stainless steel; All parts in contact with the product are made of 316 stainless steel, which complies with GMP requirements and ensures low weight of the equipment and ease of transportation.
2. The use of uniform vibration feed of material through the channels ensures reliable, smooth operation and low noise level.
3. The machine adopts a modular design with quick-release clamp connections; Partial disassembly of the structure is possible without the use of tools, which eliminates the disadvantages of traditional tablet counters, which are characterized by a complex design and inconvenient dismantling and cleaning.
4. The main drive mechanism is located inside the housing, which prevents product contamination due to wear of drive parts. All parts in contact with the product are precision polished. The machine is equipped with a dust collection box to reduce dust pollution.
5. All control system components have passed international standard certification and have passed strict input inspection tests, which guarantees the reliability of all functions.
6. All channels use three-stage vibration feed, which ensures a more uniform and smooth flow of material. The photosensitive device adopts the latest international high-resolution photosensitive technology, which compensates for the shortcomings of conventional photoelectric sensors used by domestic manufacturers. The light-sensitive technology can neutralize the influence of powder accumulated on the light screen and automatically adjust the operating state to ensure accurate counting. The equipment is equipped with a self-diagnosis system capable of detecting fragments of tablets and rejecting them, which further guarantees the accuracy of the count. The equipment generally works reliably; Changing the size of the drug is simple and convenient. The operation of the equipment is reliable, smooth, low noise, simple operation, easy maintenance, and wide applicability.
7. The touch screen interface is entirely in Chinese. Microcomputer control system based on PLC; The touch screen interface supports switching between Chinese and English at any time. The control system can store operating parameters for various drugs. The interface for interacting with the operator is friendly and ergonomic; ordinary operators can easily master working with it. Functions for cumulative counting, setting and displaying operating parameters are provided; Parameters can be arbitrarily adjusted within a given range. High degree of automation. A PLC interface is provided for receiving control signals from higher-level equipment when operating as part of a line.
8. All control system components have international standard certification and have passed strict input inspection tests, ensuring the reliability of all functions.
9. The loading nozzle fits tightly around the neck of the bottle, ensuring that large tablets do not get stuck during filling and that small tablets do not spill out. The shaking device of the loading nozzle ensures uninterrupted supply of material, eliminates the phenomenon of material getting stuck in the neck of the bottle and additionally guarantees counting accuracy. Numerous safety devices are provided, including automatic stop when bottles are missing or jammed, and conversely, automatic start of the equipment, as well as a rejection device.
10. Adopts a unique infrared photoelectric sensor, resistant to high dust levels; The counting is accurate, the counting error when filling bottles is below the requirements of the national standard. Equipped with an automatic backlight adjustment function and high dust resistance, which ensures accurate counting even for uncoated tablets with high dust content. This allows normal counting work to be carried out over a long period of time.